<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Surge archivos - Toscano</title>
	<atom:link href="https://new.toscano.es/en/category/surge/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>Diseño y fabricación de dispositivos de protección y control electricos</description>
	<lastBuildDate>Wed, 25 Mar 2026 07:39:54 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>

<image>
	<url>https://new.toscano.es/wp-content/uploads/2024/01/cropped-favicon-web-2024-2-32x32.webp</url>
	<title>Surge archivos - Toscano</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Updates in ITC REBT: Surge Protection in 2025</title>
		<link>https://new.toscano.es/en/2026/03/25/updates-in-itc-rebt-surge-protection-in-2025/</link>
		
		<dc:creator><![CDATA[jruiz]]></dc:creator>
		<pubDate>Wed, 25 Mar 2026 07:39:53 +0000</pubDate>
				<category><![CDATA[Surge]]></category>
		<guid isPermaLink="false">https://new.toscano.es/updates-in-itc-rebt-surge-protection-in-2025/</guid>

					<description><![CDATA[<p>The electricity sector in Spain is constantly evolving, driven by technological advances, compliance with European standards and the need to ensure safe and efficient installations. In this context, important updates have been introduced in the Complementary Technical Instructions (ITC) of the Low Voltage Electrotechnical Regulation (REBT) that directly affect surge protection (PCS). These modifications, scheduled [&#8230;]</p>
<p>La entrada <a href="https://new.toscano.es/en/2026/03/25/updates-in-itc-rebt-surge-protection-in-2025/">Updates in ITC REBT: Surge Protection in 2025</a> se publicó primero en <a href="https://new.toscano.es/en/">Toscano</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">The electricity sector in Spain is constantly evolving, driven by technological advances, compliance with European standards and the need to ensure safe and efficient installations. In this context, important updates have been introduced in the Complementary Technical Instructions (ITC) of the Low Voltage Electrotechnical Regulation (REBT) that directly affect surge protection (PCS). These modifications, scheduled for 2025, seek to reinforce safety in new installations and refurbishments, making it mandatory to implement both Type 1 and Type 2 protection systems.  </p>

<figure class="wp-block-image size-full"><img fetchpriority="high" decoding="async" width="785" height="269" src="https://new.toscano.es/wp-content/uploads/2025/01/Actualizaciones-en-ITC-REBT-Proteccion-contra-sobretensiones-en-2025-1.webp" alt="" class="wp-image-41460" srcset="https://new.toscano.es/wp-content/uploads/2025/01/Actualizaciones-en-ITC-REBT-Proteccion-contra-sobretensiones-en-2025-1.webp 785w, https://new.toscano.es/wp-content/uploads/2025/01/Actualizaciones-en-ITC-REBT-Proteccion-contra-sobretensiones-en-2025-1-600x206.webp 600w, https://new.toscano.es/wp-content/uploads/2025/01/Actualizaciones-en-ITC-REBT-Proteccion-contra-sobretensiones-en-2025-1-64x22.webp 64w" sizes="(max-width: 785px) 100vw, 785px" /></figure>

<h2 class="wp-block-heading">New requirements in the REBT ITCs</h2>

<p class="wp-block-paragraph">The updates in the REBT ITCs reinforce the obligation to install surge protectors (PCS) in a greater number of situations, extending their scope beyond industrial or especially vulnerable installations. The main new features are detailed below: </p>

<p class="wp-block-paragraph"><strong>Protection against direct lightning strikes (Type 1):</strong></p>

<ul class="wp-block-list">
<li>Mandatory in installations located in areas with high incidence of electrical storms or directly connected to overhead lines.</li>



<li>Type 1 PCSs are designed to withstand extremely high discharge currents and protect the installation from the point of entry.</li>
</ul>

<p class="wp-block-paragraph"><strong>Network overvoltage protection (Type 2):</strong></p>

<ul class="wp-block-list">
<li>Mandatory for all new installations and renovations of existing installations.</li>



<li>This type of PCS protects connected equipment against surges generated in the electrical system, such as voltage spikes caused by internal operations.</li>
</ul>

<p class="wp-block-paragraph"><strong>Extension of the scope of application:</strong></p>

<ul class="wp-block-list">
<li>Single-family homes, residential buildings and small businesses should also include PCS in their electrical installation designs.</li>
</ul>

<p class="wp-block-paragraph"><strong>Specific regulations for renovations:</strong></p>

<ul class="wp-block-list">
<li>Any significant refurbishment of existing installations must incorporate surge protection systems, especially if it includes changes in switchboards or line extensions.</li>
</ul>

<div style="height:50px" aria-hidden="true" class="wp-block-spacer"></div>

<figure class="wp-block-image size-full"><img decoding="async" width="785" height="269" src="https://new.toscano.es/wp-content/uploads/2025/01/Actualizaciones-en-ITC-REBT-Proteccion-contra-sobretensiones-en-2025-02-1.webp" alt="" class="wp-image-41462" srcset="https://new.toscano.es/wp-content/uploads/2025/01/Actualizaciones-en-ITC-REBT-Proteccion-contra-sobretensiones-en-2025-02-1.webp 785w, https://new.toscano.es/wp-content/uploads/2025/01/Actualizaciones-en-ITC-REBT-Proteccion-contra-sobretensiones-en-2025-02-1-600x206.webp 600w, https://new.toscano.es/wp-content/uploads/2025/01/Actualizaciones-en-ITC-REBT-Proteccion-contra-sobretensiones-en-2025-02-1-64x22.webp 64w" sizes="(max-width: 785px) 100vw, 785px" /></figure>

<h2 class="wp-block-heading"><strong>Benefits of the new provisions</strong></h2>

<p class="wp-block-paragraph">The implementation of these upgrades will bring a number of significant benefits to end users, installers and the electrical industry in general:</p>

<p class="wp-block-paragraph"><strong>Increased security:</strong></p>

<ul class="wp-block-list">
<li>The installation of PCS reduces the risk of electrical accidents and damage to equipment, also minimizing the possibility of fires caused by power surges.</li>
</ul>

<p class="wp-block-paragraph"><strong>Investment protection:</strong></p>

<ul class="wp-block-list">
<li>By preventing equipment damage, companies and individuals can avoid unforeseen expenses for repairs or replacements.</li>
</ul>

<p class="wp-block-paragraph"><strong>Regulatory compliance:</strong></p>

<ul class="wp-block-list">
<li>The upgrades ensure that installations are aligned with European standards, facilitating the homologation and export of projects.</li>
</ul>

<p class="wp-block-paragraph"><strong>Promoting sustainability:</strong></p>

<ul class="wp-block-list">
<li>Protection systems contribute to a more efficient use of energy resources and reduce the environmental impact associated with equipment rendered inoperative due to power surges.</li>
</ul>

<h2 class="wp-block-heading">Impact on the installation sector</h2>

<p class="wp-block-paragraph">The changes in the ITC also imply challenges and opportunities for electrical installers:</p>

<ul class="wp-block-list">
<li><strong>Training:</strong> Installers should keep up to date on new regulations and commercially available equipment to meet requirements.</li>



<li><strong>Increase in services:</strong> The requirement to install PCS in more situations means an increase in work for the sector, as well as the need to advise clients on the best solutions.</li>



<li><strong>Adaptation to modern technologies:</strong> PCS systems are evolving rapidly, including intelligent options that allow real-time monitoring of installation conditions.</li>
</ul>

<div style="height:70px" aria-hidden="true" class="wp-block-spacer"></div>

<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<figure class="wp-block-image size-full"><img decoding="async" src="https://toscano.es/wp-content/uploads/2022/02/combi-pro-p.webp" alt="" class="wp-image-38457"/></figure>



<h4 class="wp-block-heading">COMBI-PRO</h4>



<p class="wp-block-paragraph">Transient, permanent and undervoltage surge protector. With automatic reconnection. </p>



<div class="wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex">
<div class="wp-block-button"><a class="wp-block-button__link wp-element-button" href="https://toscano.es/producto/combi-pro-2pt/">SEE EQUIPMENT</a></div>
</div>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<figure class="wp-block-image size-full"><img decoding="async" width="640" height="640" src="https://new.toscano.es/wp-content/uploads/2021/12/COMBI-2P-MINI.webp" alt="" class="wp-image-35340" srcset="https://new.toscano.es/wp-content/uploads/2021/12/COMBI-2P-MINI.webp 640w, https://new.toscano.es/wp-content/uploads/2021/12/COMBI-2P-MINI-300x300.webp 300w, https://new.toscano.es/wp-content/uploads/2021/12/COMBI-2P-MINI-600x600.webp 600w, https://new.toscano.es/wp-content/uploads/2021/12/COMBI-2P-MINI-100x100.webp 100w, https://new.toscano.es/wp-content/uploads/2021/12/COMBI-2P-MINI-64x64.webp 64w" sizes="(max-width: 640px) 100vw, 640px" /></figure>



<h4 class="wp-block-heading">COMBI-MINI</h4>



<p class="wp-block-paragraph">Transient and permanent surge arrester. For single phase lines.   </p>



<div class="wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex">
<div class="wp-block-button"><a class="wp-block-button__link wp-element-button" href="https://toscano.es/producto/combi-mini-2pt/">SEE EQUIPMENT</a></div>
</div>
</div>
</div>

<p class="wp-block-paragraph"></p>
<p>La entrada <a href="https://new.toscano.es/en/2026/03/25/updates-in-itc-rebt-surge-protection-in-2025/">Updates in ITC REBT: Surge Protection in 2025</a> se publicó primero en <a href="https://new.toscano.es/en/">Toscano</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to use COMBI-MINI to comply with ITC-BT-52 and protect your electrical installation</title>
		<link>https://new.toscano.es/en/2026/03/25/how-to-use-combi-mini-to-comply-with-itc-bt-52-and-protect-your-electrical-installation/</link>
		
		<dc:creator><![CDATA[jruiz]]></dc:creator>
		<pubDate>Wed, 25 Mar 2026 07:39:53 +0000</pubDate>
				<category><![CDATA[Surge]]></category>
		<category><![CDATA[Recharging point]]></category>
		<guid isPermaLink="false">https://new.toscano.es/how-to-use-combi-mini-to-comply-with-itc-bt-52-and-protect-your-electrical-installation/</guid>

					<description><![CDATA[<p>The ITC-BT-52 standard, which regulates installations for charging electric vehicles, establishes specific requirements for the safety and efficiency of electrical infrastructures in homes. An important aspect of this regulation is diagram 2, which mentions how to handle trips due to excess meter consumption and the resetting process from inside the home. In this article, we [&#8230;]</p>
<p>La entrada <a href="https://new.toscano.es/en/2026/03/25/how-to-use-combi-mini-to-comply-with-itc-bt-52-and-protect-your-electrical-installation/">How to use COMBI-MINI to comply with ITC-BT-52 and protect your electrical installation</a> se publicó primero en <a href="https://new.toscano.es/en/">Toscano</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">The <strong>ITC-BT-52</strong> standard, which regulates installations for charging electric vehicles, establishes specific requirements for the safety and efficiency of electrical infrastructures in homes. An important aspect of this regulation is diagram 2, which mentions how to handle trips due to excess meter consumption and the resetting process from inside the home. </p>

<p class="wp-block-paragraph">In this article, we will explore how the use of devices such as the <strong>COMBI MINI</strong> can help you meet these regulatory requirements by providing adequate overvoltage protection and ensuring safe and efficient resetting of the meter in the event of a trip.</p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="645" height="272" src="https://new.toscano.es/wp-content/uploads/2024/09/newslertter-fenie-2.webp" alt="" class="wp-image-41210" srcset="https://new.toscano.es/wp-content/uploads/2024/09/newslertter-fenie-2.webp 645w, https://new.toscano.es/wp-content/uploads/2024/09/newslertter-fenie-2-600x253.webp 600w, https://new.toscano.es/wp-content/uploads/2024/09/newslertter-fenie-2-64x27.webp 64w" sizes="(max-width: 645px) 100vw, 645px" /></figure>

<h4 class="wp-block-heading"><strong>What is ITC-BT-52 and why is it important?</strong></h4>

<p class="wp-block-paragraph"><strong>ITC-BT-52</strong> is a technical instruction complementary to the Low Voltage Electrotechnical Regulation (REBT), focused on electrical installations for electric vehicle charging. This regulation seeks to ensure that all installations meet the safety and efficiency standards required for the daily use of charge points in domestic and commercial environments. </p>

<p class="wp-block-paragraph">According to diagram 2 of ITC-BT-52, in the event of a meter trip due to over-consumption, <strong>it must be possible to reset the</strong> meter <strong>from inside the dwelling</strong>. This means that the systems must be designed in such a way that it is not necessary to leave the house to restore the power supply, improving the safety and comfort of the user. </p>

<h4 class="wp-block-heading"><strong>COMBI MINI with infinite impedance</strong></h4>

<p class="wp-block-paragraph">The <strong>COMBI MINI</strong> is a compact protection device designed to protect electrical installations against transient and permanent overvoltages. An outstanding feature of this equipment is its <strong>infinite impedance</strong>, which means that the COMBI MINI is not &#8220;visible&#8221; to the energy meter. In simple terms, its infinite impedance means that it does not affect the consumption measurement circuit, which allows the meter to not detect the device as an additional load.  </p>

<h5 class="wp-block-heading"><strong>How does the COMBI MINI facilitate meter resetting?</strong></h5>

<p class="wp-block-paragraph">Thanks to this <strong>infinite impedance</strong> feature, the <strong>COMBI MINI</strong> allows the energy meter, when triggered by excess consumption, to be reset without the need for additional cut-off elements or automatic reset systems.</p>

<h3 class="wp-block-heading"><strong>Expansion on infinite impedance chargers</strong></h3>

<p class="wp-block-paragraph">In order for the entire electric vehicle charging system to be <strong>“invisible” to the smart meter</strong>, it is necessary that both the <strong>COMBI MINI</strong> and the vehicle <strong>charger</strong> have <strong>infinite impedance</strong>.</p>

<h4 class="wp-block-heading"><strong>What does this mean?</strong></h4>

<p class="wp-block-paragraph">A <strong>charger with infinite impedance</strong> is one that, like the COMBI MINI, is not detected by the energy meter in the event of tripping by ICP. In other words, the meter does not perceive the charger as an additional load because the infinite impedance prevents current from being registered in the meter&#8217;s measuring circuit. </p>

<h4 class="wp-block-heading"><strong>Why is it important to combine both devices?</strong></h4>

<ul class="wp-block-list">
<li><strong>COMBI MINI + Charger with Infinite Impedance:</strong> When both devices have <strong>infinite impedance</strong>, it allows that, in the event of a trip due to excess consumption, the meter <strong>reset</strong> can be carried out without problems from the home, since neither the charger nor the COMBI-MINI is detected.</li>



<li><strong>Completely invisible system:</strong> If only one of the devices (COMBI MINI or the charger) has infinite impedance, the other could be detected as a load, which would make resetting the meter more complicated. It is therefore essential that both have this feature to ensure that the recharging system is completely invisible to the meter. </li>
</ul>

<h4 class="wp-block-heading"><strong>What to do if the charger does not have infinite impedance?</strong></h4>

<p class="wp-block-paragraph">In case the car charger does not have <strong>infinite impedance</strong>, and therefore the smart meter detects all connected loads, it is necessary to use an additional solution to protect the installation against overvoltage, such as our COMBI-PRO.</p>
<p>La entrada <a href="https://new.toscano.es/en/2026/03/25/how-to-use-combi-mini-to-comply-with-itc-bt-52-and-protect-your-electrical-installation/">How to use COMBI-MINI to comply with ITC-BT-52 and protect your electrical installation</a> se publicó primero en <a href="https://new.toscano.es/en/">Toscano</a>.</p>